The 2 Hour Fire Rated, 36 dB Acoustic & Smoke Tested Heavy Duty Wall Access Panel is engineered to provide secure and reliable access to concealed wall services while maintaining the integrity of fire-rated wall systems. Constructed with a robust 1.2 mm thick metal door leaf and 1.5 mm thick steel frame, this heavy-duty access panel is built for long-lasting performance in commercial, industrial, and residential environments.
Featuring a 25 mm wide picture frame, 3-point locking system, and the Rapid Fit Hinge System, the panel ensures enhanced security while allowing for quick and efficient installation. Finished with a durable RAL 9010 (30% Gloss) powder coating, it provides a clean, professional appearance suitable for a wide range of interior applications.
This access panel has been independently fire tested from both sides in accordance with BS EN 1634-1:2008 + A1 and BS EN 1363-1:1999, providing up to 2 hours of fire resistance. It is also acoustically rated up to 36 dB in accordance with BS EN ISO 10140-2:2010 and smoke tested to BS EN 1634-3:2004, making it an ideal solution where fire protection, sound insulation, and smoke control are essential.
Key Features
- 2 Hour Fire Rated
- 36 dB Acoustic Rated
- Smoke Tested
- 1.2 mm Thick Metal Door Leaf
- 1.5 mm Thick Steel Frame
- Rapid Fit Hinge System
- 25 mm Wide Picture Frame
- 3 Point Locking System
- Single Door Design
- Powder Coated Finish
- RAL 9010 (30% Gloss)
- Suitable for Wall Installations
Fire, Acoustic & Smoke Certification
This wall access panel has been independently tested to meet recognised fire, acoustic, and smoke performance standards.
- Fire Test Standards: BS EN 1634-1:2008 + A1 & BS EN 1363-1:1999
- Fire Test Report Numbers: RF13137 (Rear) & 434360 (Seen Face)
- Fire Tested From: Both Sides
- Certified Wall Application Size: Up to 2400 × 900 mm
- Panels larger than the tested size are manufactured using the same construction specification as the tested model.
- Acoustic Test Standard: BS EN ISO 10140-2:2010
- Acoustic Rating: Up to 36 dB
- Acoustic Report Number: Z13037
- Smoke Test Standard: BS EN 1634-3:2004
- Smoke Test Report Number: WYC415771
Installation Notes
- Designed for wall installations.
- The first dimension specified represents the hinge side.
- Supplied as a single door unit.